1.0 Description

The N×1 Multimode Pump Combiners (MPC) is designed for combining pump laser into the main fiber. The MPC can be applied into the high power fiber laser and fiber amplifier.

2.0 Optical and Operation Specifications

Item Specifications Min. Typ. Max. Unit Notes
2.01 Pump wavelength 800 1000 nm
2.02 Polarization Random PM Customizable
2.03 Operation regime CW
2.04 Fiber length 1.0 m Default
2.05 Operating temperature range 0 +70 °C
2.06 Storage temperature -40 +85 °C
2.07 Cooling method Bottom conduction cooling

3.0 Typical fiber combinations

Item Confi. Pump Fiber Type Output Fiber Type Pump Efficiency Power
Handling
Package
3.01 3×1 105/125, 0.22NA
106.5/125, 0.22NA
220/242 MMF, 0.22NA
225/240 MMF, 0.22NA
97% 200W/leg A –
100*15*11
135/155, 0.22NA 220/242 MMF, 0.22NA
225/240 MMF, 0.22NA
95% 200W/leg A –
100*15*11
3.02 4×1 105/125, 0.22NA
106.5/125, 0.22NA
220/242 MMF, 0.22NA
225/240 MMF, 0.22NA
96% 200W/leg A –
100*15*11
3.03 7×1 105/125, 0.22NA
106.5/125, 0.22NA
220/242 MMF, 0.22NA
225/240 MMF, 0.22NA
95% 200W/leg A –
100*15*11
3.04 105/125, 0.22NA
106.5/125, 0.22NA
X/125 DCF, 0.075NA
X/250 DCF, 0.06NA
X/400 DCF, 0.06NA
97% 200W/leg B –
150*15*12
3.05 200/220 MMF, 0.22NA
220/242 MMF, 0.22NA
225/240 MMF, 0.22NA
X/400 DCF, 0.06NA 97% 400W/leg B –
150*15*12
3.06 19×1 105/125, 0.22NA
106.5/125, 0.22NA
135/155, 0.22NA
X/400 DCF, 0.06NA 96% 150W/leg B –
150*15*12
* X=6, 8, 10, 15, 20,  25, 30 etc.
* Better performance and other configuration can all be customized.

4.0 Mechanical specifications and drawings

Item Specifications Unit Notes
4.01 Module’s Dimensions 100*15*11 mm Bottom conduction cooling
Item Specifications Notes Notes
4.02 Module’s Dimensions 150*15*12 mm Bottom conduction cooling

5.0 Ordering information

MPC-----/-
Port combination Pump fiber type Output fiber type
3 – 3×1
4 – 4×1
7 – 7×1
19– 19×1
M01 – 105/125, 0.22NA
M02 – 106.5/125, 0.22NA
M03 – 135/155, 0.22NA
ect.
D00 – 10/130 DCF, 0.075NA
M05 – 220/242 MMF, 0.22NA
M06 – 225/240 MMF, 0.22NA
ect.
Pump power per port /Pump/Output fiber length Package type
100 – 100W
200 – 200W
250 – 250W
ect.
1.0 – 1.0m Default
1.5 – 1.5m
2.0 – 2.0m
ect.
A – Aluminum package 100*15*11
B – Aluminum package 150*15*12
S – Specify