GYXTY aðal lausar rör stál ljósleiðari

Steel Wire Armored Uni-Tube optical cable with fibers placed in loose buffer tube.The cable core is protected with jelly to prevent water intrusion and migration, protected with steel wire armor. The whole set cover with a black polyethylene outer jacket.


Color:

    Vöruupplýsingar

    Lýsing
    Steel Wire Armored Uni-Tube optical cable with fibers placed in loose buffer tube.The cable core is protected with jelly to prevent water intrusion and migration, protected with steel wire armor. The whole set cover with a black polyethylene outer jacket.
    Cable cross-section

    Cable Specification
    2.1 Inngangur
    Mið laus laus rör, hlaupasambönd fyllt, brynvarðar stálvír og ytri hlíf PE.
    2.2 Trefjulitakóði
    Trefjuliturinn í hverju túpu byrjar frá nr. 1 bláu.
    Nei. 1 2 3 4 5 6
    Litur 1.Blue fiber-Qualfiber
    Nei. 7 8 9 10 11 12
    Litur
    Nei. 13 14 15 16 17 18
    Litur
    Nei. 19 20 21 22 23 24
    Litur

    Athugasemd: * S100 þýðir bil 100 mm svartur hringur.
               * Með áhrifum ljóss og annarra þátta getur raunverulegur litur haft smá frávik, litirnir hér að ofan á myndinni eingöngu til viðmiðunar.
    2.3 Litakóði fyrir lausa
    slönguna Liturinn á rörinu er eðli eða Hvítur
    .
    2.4 Kapalbygging og færibreytur

    SN Liður Eining Gildi
    1 Fjöldi trefja telja 8 ~ 16
    2 Þvermál slöngunnar mm 3.6
    3 Stálvír mm 1,0
    4 Þvermál snúrunnar mm 9.7
    5 Þyngd snúrunnar kg / km 155
    6 Skammtímaspenna N 2500
    7 Skammtímaskreyting N / 100mm 2000


    3. Einkennandi fyrir ljósleiðara
    3.1 mín. beygja radíus fyrir uppsetningu
    Static: 15 x snúrur þvermál
    Dynamic: 30 x snúru þvermál
    3.2 Hiti svið notkunar
    Operation:  - 10℃ ~ +60℃
    Uppsetning: -10 ℃ ~ + 60 ℃
    Storage/transportation:  - 40℃ ~ +60℃
    3.3 Helstu vélrænni & umhverfisprófun

    Liður Prófunaraðferð Samþykki Skilyrði
    Togstyrkur
    IEC 794-1-2-E1
    - Hleðsla: Skammtímaspenning
    - Length of cable: about 50m
    - Trefjar stofn £ 0,6%
    - No fiber break and no sheath damage.
    Mylja Test
    IEC 60794-1-2-E3
    - Hleðsla: Skammtíma troðningur
    - Load time: 1min
    - Tapsbreyting £ 0,05 dB@1550nm
    - No fiber break and no sheath damage.
    Áhrif Test
    IEC 60794-1-2-E4
    - Höggpunktar: 3
    - Times of per point: 1
    - Impact energy: 5J
    - Tapsbreyting £ 0,1dB@1550nm
    - No fiber break and no sheath damage.

    4. Einkenni Optical Fiber
    G652 trefjarupplýsinga
    Mode sviði þvermál (1310nm): 9,2mm ± 0,4mm
    Mode field þvermál (1550nm): 10,4mm ± 0,8mm
    Skera af bylgjulengd snúru trefja (l cc ): £ 1260nm
    Attenuation at 1310nm: 0,36dB / km aðdrátt
    við 1550nm: 0,22 dB / km Beygistap
    við 1550nm (100 snúninga, 30 mm radíus): £ 0,05 dB
    dreifing á bilinu 1288 til 1339nm: £ 3,5ps / (nm • km)
    Dreifing við 1550nm: 18 pund / (nm • km)
    Dreifingarhalli við núll dreifibylgjulengd: 0,092 pund / (nm 2• km)